BVJWB - SHAFT LAC 1,1,1 CAT YELLOW 340, 338Y019
- MSDS: BVJWB
- Manufacturer: ELLIS PAINT CO
- Product Name: SHAFT LAC 1,1,1 CAT YELLOW 340, 338Y019
- National Stock Number: 8010-00N050500
Product Identification
Product ID:SHAFT LAC 1,1,1 CAT YELLOW 340, 338Y019
MSDS Date:12/06/1990
FSC:8010
NIIN:00N050500
MSDS Number: BVJWB
Responsible Party
LOS ANGELES, CA 90023
US
Emergency Phone: 213-261-8114
Info Phone: 213-261-8114
Cage: 04GC9
Contractor
Telephone: 323-261-8114
Cage: 0RGC9
Ingredients
28 @ 68F.
CAS: 107-87-9
RTECS: SA7875000
Fraction By Weight: 10%
OSHA PEL 200 PPM;250 STEL
ACGIH TLV: 200 PPM;250 STEL
70 @ 68F.
CAS: 78-93-3
RTECS: EL6475000
Fraction By Weight: 1%
OSHA PEL 200 PPM;300 STEL
ACGIH TLV: 200 PPM;300 STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
22 @ 68F.
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 1%
OSHA PEL 200 PPM;150 STEL
ACGIH TLV: 50 PPM
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
53 @ 77F.
CAS: 8030-30-6
RTECS: DE3030000
Fraction By Weight: <5%
OSHA PEL 100 PPM (MFR)
ACGIH TLV: 300 PPM (MFR)
30 @ 77F.
CAS: 8032-32-4
RTECS: OI6180000
Fraction By Weight: <5%
OSHA PEL 300 PPM;400 STEL
ACGIH TLV: 300 PPM
33 @ 68F.
CAS: 67-63-0
RTECS: NT8050000
Fraction By Weight: <0.5%
OSHA PEL 400 PPM;500 STEL
ACGIH TLV: 400 PPM;500 STEL
3 @ 68F.
CAS: 71-55-6
RTECS: KJ2975000
Fraction By Weight: 13%
OSHA PEL 350 PPM;450 STEL
ACGIH TLV: 350 PPM;450 STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
C.I. PIGMENT YELLOW 42; (IRON OXIDE HYDRATE)
CAS: 51274-00-1
Fraction By Weight: <5%
OSHA PEL 15 MG/M3 (MFR)
ACGIH TLV: 10 MG/M3 (MFR)
2 @
CAS: 64741-41-9
Fraction By Weight: <5%
OSHA PEL 500 PPM (MFR)
ACGIH TLV: 100 PPM (MFR)
PROPIONIC ACID, 3-ETHOXY-, ETHYL ESTER;
CAS: 763-69-9
RTECS: UF3325000
Fraction By Weight: <5%
OSHA PEL N/K
ACGIH TLV: 50 PPM (MFR)
2.49 LB/GAL (298
RTECS: 9999999VO
Fraction By Weight: SEE ING
9 @ 68F.
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: 10%
OSHA PEL 100 PPM;150 STEL
ACGIH TLV: 100 PPM;150 STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:MAY CAUSE EYE, NOSE & RESP TRACT
IRRIT, HDCH, DROW & NAUS. INGEST MAY CAUSE VOMIT & SUBSEQUENT ASPIR
OF LIQ INTO LUNGS MAY LEAD TO CHEM PNEUM & PULM EDEMA. INHAL:MAY
CAUSE DIZZ, HDCH, NAUS & LOS S OF COORD. EYE CONT:MAY CAUSE
DISCOMFORT & IRRIT. SKIN:CONT MAY CAUSE IRRIT. ABSORPTION MAY CAUSE
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:DERM. INGEST:MAY CAUSE GI IRRIT, NAUS,
VOMIT & DIARR. CHRONIC:LONG TERM EXPOS MAY LEAD TO CNS DEPRESS.
NOTE:TOLUENE APPEARS ON NAVY LIST OF OCCUP CHEM REPRO HAZS. SEEK
CONSULTATION FROM APPRO P HLTH PROFESSIONALS CONCERNING LATEST HAZ
LIST INFO & SAFE HNDLG & EXPOS INFO . CHLOROCARBON MATLS HAVE
(SUPDAT)
Medical Cond Aggravated by Exposure:PRE-EXISTING EYE, SKIN &
RESPIRATORY DISORDERS MAY BE AGGRAVATED.
First Aid
First Aid:INHAL:REMOVE TO FRESH AIR & PROVIDE OXYGEN IF BREATHING IS
DIFFICULT. EYES:FLUSH IMMED W/LARGE AMOUNTS OF WATER FOR AT LEAST
15 MINUTES. SKIN:WASH AFFECTED AREA W/SOAP & WATER. REMOVE
CONTAMINATED CLO THING. INGEST:DO NOT INDUCE VOMITING. IF VOMITING
OCCURS SPONTANEOUSLY, KEEP HEAD BELOW HIPS TO PREVENT ASPIRATION OF
LIQUID INTO LUNGS. GET MED ATTN IMMED.
Fire Fighting
Flash Point Method:TCC
Flash Point:23.0F,-5.0C
Lower Limits:0.9%
Upper Limits:15%
Extinguishing Media:FOAM, CO*2, DRY CHEMICAL, WATER FOG.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA &
FULL PROTECTIVE EQUIPMENT . DO NOT USE DIRECT STREAM OF WATER.
Unusual Fire/Explosion Hazard:FIRE-EXPOS CNTNRS SHOULD BE COOLED
W/WATER TO PVNT PRESS BUILD-UP WHICH COULD RSLT IN CNTNR RUPTURE.
THERMAL DECOMP PRODS MAY INCLUDE HCL & PHOSGENE .
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION & PROVIDE
VENTILATION. LARGE SPILLS MAY BE SCOOPED UP W/NON-SPARKING TOOLS.
SMALL SPILLS MAY BE PICKED UP W/ABSORBENT MATERIALS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE AWAY FROM HIGH TEMPS, SPKS &
OPEN FLAMES. KEEP CNTNRS TIGHTLY CLSD. DO NOT TAKE INTERNALLY.
AVOID PRLNG CONTACT. SMOKE IN SMOKING AREAS ONLY
Other Precautions:DO NOT PACKAGE IN ALUMINUM AEROSOL CANS OR W/FINELY
DIVIDED ALUMINUM/ITS ALLOYS IN AEROSOL CAN. NO SMOKING IN AREA OF
USE. DO NOT USE IN GEN VICIN OF ARC WELDING, OPEN FLAMES/HOT SURFS.
HEAT &/OR UV R ADIA MAY CAUSE FORM OF HCL &/OR (SUPDAT)
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED SCBA WHERE VAPOR
CONCENTRATION MAY BE ABOVE TLV LIMITS. USE NIOSH/MSHA APPROVED
RESPIRATORS WHERE VAPOR CONCENTRATION DOES NOT EXCEED TLV LIMITS.
Ventilation:ADEQUATE VOLUME & PATTERN TO CONTROL AIRBORNE
CONCENTRATIONS BELOW EXPOSURE GUIDELINES.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPVD CHEMICAL GOGGLES .
Other Protective Equipment:SAFETY SHOWER & EYE BATH WHICH MEET ANSI
DESIGN CRITERIA .
Work Hygienic Practices:WASH HANDS BEFORE EATING OR USING THE WASHROOM.
Supplemental Safety and Health
EFTS OF OVEREXP:PRDCD SENSIT OF MYOCARDIUM TO EPINEPHRINE IN LAB
ANIMALS & COULD HAVE SIMILAR EFT IN HUMANS. ADRENOMIMETICS (E.G.,
EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT FOR LIFE-SUSTAINING USES
I N HUMANS ACUTELY/CHRONICALLY EXPOS TO CHLOROCARBONS . OTHER
PREC:PHOSGENE .
Chemical Properties
Boiling Pt:B.P. Text:>165F,>74C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:1 (H*2O=1)
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:INSOLUBLE
Appearance and Odor:YELLOW LIQUID W/MILD ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
METALLIC ALUMINUM, ZINC POWDERS & LONG TERM CONTACT W/WATER.
Stability Condition to Avoid:OPEN FLAMES, WELDING ARCS OR OTHER HIGH
TEMPERATURE SOURCES.
Hazardous Decomposition Products:THERMAL DECOMPOSITION MAY YIELD CARBON
DIOXIDE, CARBON MONOXIDE, HYDROGEN CHLORIDE & TRACES OF PHOSGENE &
CHLORINE.
Disposal
Waste Disposal Methods:PLACE IN TIGHTLY CLOSED CONTAINERS. INCINERATE
OR DISPOSE OF I/A/W LOCAL, STATE & FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.